Control and regulating system for pH and Redox, made of eSELECT-M2 controller, block valves, connection for tube 10x14 mm, water filter with washable net cartridge 150 microns, methacrylate probe holder, pH electrode with plastic body with cable 1 mt (Tmax=60° C Pmax=6 bar) working range 0÷14 pH, Redox electrode with plastic body with cable 1 mt (Tmax=60° C Pmax=6 bar) working range ± 1.000 mV, 4 buffer solution 55ml bottles (pH 4, 7, 9 and Redox 650 mV), 2 manual pumps wiring connection available in the central box trunking. Suitable for software EtaCloud connection; optional accessory: connectivity kit.
Panel dimensions 400 x 600 x 0.80 mm
Control and regulating system for pH and Redox, made of eSELECT-M2 controller, block valves, connection for tube 10x14 mm, water
filter with washable net cartridge 150 microns, methacrylate probe holder with proximity switch and adjustment flow system, manual
sampling, pH electrode with plastic body with cable 1 mt (Tmax=60° C Pmax=6 bar) working range 0÷14 pH, Redox electrode with
plastic body with cable 1 mt (Tmax=60° C Pmax=6 bar) working range ± 1.000 mV, 4 buffer solution 55ml bottles (pH 4, 7, 9 and Redox
650 mV), 2 manual pumps wiring connection available in the central box trunking. Suitable for software EtaCloud connection; optional accessory: connectivity kit.
Panel dimensions 400 x 600 x 0.80 mm
Control and regulating system for free chlorine, made of eSELECT-M1 controller, block valves, connection for tube 10x14 mm, water
filter with washable net cartridge 150 microns, methacrylate probe holder with proximity switch and adjustment flow system, manual
sampling, free inorganic and organic chlorine probe, (0 – 20) ppm measuring range, probe shows low pH dependence (pH working
range 4- 12 pH), chlorine measuring is not affected by isocyanuric acid, surfactants/flocculants presence, the probe is automatic temperature-
compensated, 0,7 mt probe cable, 1 manual pump wiring connection available in the central box trunking. The unit required a
constant flow rate between 30 and 40 l/h, do not exceed the maximum operating pressure of 1 bar (free discharge at probe holder outlet)
while water temperature cannot overcome 45°C. The probe has integrated temperature compensation. Suitable for software EtaCloud connection; optional accessory: connectivity kit.
Panel dimensions 400 x 600 x 0.80 mm
Control and regulating system for free chlorine and pH, made of eSELECT-M2 controller, block valves, connection for tube 10x14 mm, water
filter with washable net cartridge 150 microns, methacrylate probe holder with proximity switch and adjustment flow system, manual sampling,
free inorganic and organic chlorine probe, (0 – 20) ppm measuring range, probe shows low pH dependence (pH working range 4-12 pH), chlorine
measuring is not affected by isocyanuric acid, surfactants/flocculants presence, the probe is automatic temperature-compensated, 0,7 mt
probe cable, pH electrode with plastic body with cable 1 mt (Tmax=60° C Pmax=6 bar) working range 0÷14 pH, 3 buffer solution 55ml bottles
(pH 4, 7 and 9), 2 manual pumps wiring connection available in the central box trunking. The unit required a constant flow rate between 30 and
40l/h, do not exceed the maximum operating pressure of 1 bar (free discharge at probe holder outlet) while water temperature cannot overcome
45°C. The probe has integrated temperature compensation. Suitable for software EtaCloud connection; optional accessory: connectivity kit.
Panel dimensions 400 x 600 x 0.80 mm
Measure and control instruments.eControl series controllers are designed to be used in all applications where continuous measurement of the chemical
parameters of the water is required. They are made with the use of microcontrollers and have a galvanically isolated
measurement stage. The versions are available with single or double measuring channels, independently configurable